Basement Vapor Barrier For Basement Insulation

Basement Vapor Barrier and Insulation

We’ve written several articles about basement insulation and a cost effective approach to basement insulation using foam board and fiberglass insulation. Since writing those articles we’ve received quite a few questions about when to use a basement vapor barrier and when not to. So we thought it might be a good idea to clear up some of the confusion.

Understanding Vapor Movement

Before we explain where to use vapor barriers it’s a good idea to talk about where the vapor comes from which ultimately makes the discussion easier to understand.

First off you need to think of your concrete (or block) walls as a huge sponge for moisture (water vapor). Over time and throughout seasonal changes in temperature concrete will “dry” out releasing a tremendous amount of water vapor. The adjacent sketch shows an unfinished, un-insulated, un-heated basement wall. We’ve shown arrows that indicate where the water vapor goes as the wall “dries” out.

Depending on the time of year it’s possible that all that humidity in the air will turn around and condensate on the cool concrete surface if the dew point is correct. The point here though is how moisture in the form of water vapor leaves the foundation walls and migrates into the basement space or outside above grade.

Page: 1 2 3

Todd Fratzel

I'm full time builder for a large construction company in New Hampshire. I run their design-build division that specializes in custom homes, commercial design-build projects and sub-divisions. I'm also a licensed civil and structural engineer with extensive experience in civil and structural design and home construction. My hope is that I can share my experience in the home construction, home improvement and home renovation profession with other builders and home owners. I'm also the Editor-in-Chief and Founder of Tool Box Buzz. Please feel free to contact me if you have any questions, suggestions or you'd like to inquire about advertising on this site.

View Comments

  • Hi Todd.

    Not sure if you replied but i can't find the page i posted my question on.

    I was interested in following your article above on how to insulate the basement and vapor barriers, etc.I noticed how you said frame infront of the foam and to leave a one inch space between for air flow.

    How do i help to keep the foam attached to the wall?? I was going to use an adhesive and then frame up against to keep it in place, but the air space you said was better.

    Can i use wall anchors for the foam too?? I was concerned if they work on my old basement wall.

    Also, my township requires horizontal and vertical fireblocking. How do i incorporate this into your instructions and diagram above and still be in code??

    Note: i am not covering or finishing my ceiling. my head height is too low so i will just leave it open and paint instead.

    Thanks for all your help.
    Rob A.

    • @ Rob – We typically use an adhesive specifically made for foam board. The key is to put the adhesive on the foam and let it sit for a few mins before you apply to the wall. That allows a skim to form on the glue and it sticks better to the wall. I’m not sure the fire blocking is applicable in your situation. It’s typically applicable with balloon framing which you will not have in this situation. It’s best to check with your building inspector ahead of time and find out what he/she wants. Good luck.

  • Thanks Todd.

    I'll be using the blue foam and adhering the silver side on to the wall and blue side facing into the room, correct??

    My township website shows a diagram of the fire blocking on a finished basement wall, and uses horizontal and vertical blocking. it says they require vertical fire blocking at 10ft intervals.

    Seems unnecessary to me too, but i'll need to talk to them first and explain what i'll be doing then see what they say.

    Thanks,
    Rob A.

    • @ Rob - What foam product are you using? Without knowing which product it's hard to say which face goes towards the concrete.

  • Hi Todd.

    it's the SUPER TUFF-R 1 1/2 In. 4 x 8 Polyisocyanurate Rigid Foam Insulation. it's silver on one side and blue on the other.

    Is this the best to use??

  • Hi Todd

    I live in southern Missouri, cold but not extreme, I'd like to cover the poured basement walls. I'm thinking about glueing foamboard between 2x2 furring strips and paneling over it. Any reason not to?. I don't think I need the additioanl insulation value a fiberglass-inside 2-4 stud wall would provide. Ceiling is insulated with plastic covered fiberglass and will be covered with drywall. Walls have been uncovered for 15 years so they are as dry as they will be. We use a de-humidifer ithe room. Most of wall area is completely below grade. Also if I can use this set up, do I need a platic vapor barrier under paneling? What type of formaldehyde free foamboard do you redommend? Thanks for your advice. G. Brewer

    • @ Gary - I would glue the foam board directly to the concrete. Then place your furring over the foam and secure it through the foam into the concrete. Either that or frame a wall in front of the foam. Be sure to tape the seams well. No need for a vapor barrier. Good luck!

      • todd,
        my basement foundations walls were very poorly poured in 1952 w many honeycombs, air pockets, and poor adhesion between poors.when we would get as little as a 1/4 inch of rain i had water running across the floors. for this problem i have installed a complete interior seepage drain system in my basement that also has a lip that sits above the floor against wall that collects any seepage water off walls.i corrected any outdoor water problems-downspouts,improperly sloped concrete,terrain,etc. i have also applied hydraulic cement after chipping out concrete in any spots on walls that still had visible water seepage,i then applied dry lock paint to these areas. this has taken care of any visible moisture on walls or floors after heavy rains--(recently 3")dry is nice. i have also put in a radon mitigation system that is sucking air from under my basement slab through the seepage drain system so any moist air is being removed off of foundation wall(the design was to remove radon but by incorporating it with the seepage system im also pulling air from the moist foundation wall through the earlier mentioned lip against wall). with all this being said i'm currently furring out the walls staying 6" off foundation wall,treated lumber for bottom plate,fiberglass insulation in void between floor joists on sill plate against ribbon joist,below this foam board insulation-to prevent mold- from top of foundation wall 4' down-not the whole stud space- flush with drywall face of stud. does all this sound ok and should i install vapor barrier between foam insulation and drywall. i know this sounds like a lot of information but i figured the more descriptive the better. thank you for your assistance in this matter.
        chris

  • Reading your article has made me re-think my approach to insulating my basement walls. I live in Upstate NY, where the Winters are brutally cold. My 5-year old house has block basement walls.

    I decided to experiment with one wall and installed the DOW 2" rigid foam board, and am building a standard 2x4 wall as well. I intended to fill it with R-13 fiberglass insulation.

    One question, however. I am not sure if I should use a faced insulation or not. According to your article, it seems unnecesary (since I am using 2" foam), however I cannot find any rolls of R-13 unfaced fiberglass at the box stores! I can find R-13 pre-cut batts, but they are twice the price and will result in about 6" of waste per batt. Any suggestions? Alternative include (1) using R-19 for 2x6 walls and compressing it (bad), or using R-13 faced rolls.

    Many thanks for your insightful article.

    -Todd M

    • @ Todd M - Thanks for visiting the site. The vapor barrier won't do any harm in your situation. If that's the cheapest product available then I say go with it. Good luck.

  • Hello Todd,
    I am having my basement redone after a fire. The basement was previously finished with chip board paneling partially over framing and partially directly on the concrete. We will be using dry wall. The building contractor I am using for the rebuild has framed out the wall with TYVEX behind it. He says that it's not necessary to put in insulation behind the dry wall because the air space and the soil around the foundation will provide all the insulation needed. The basement has never had moisture on any of the walls, but it is always colder in the winter and summer then the rest of the house. Is my contractor correct, or should I insist on insulation on the outside walls of the basement?

    Thanks,

    Greg M

    • @ Greg M - First off it partially depends on where you live. However, I would insulate it regardless if it were my home. Secondly, Tyvek will actually allow water vapor to move through it in one direction so technically the water vapor "could" move from the foundation to the framing depending on the side that is towards the framing. Frankly even a "dry" looking foundation was is extremely damp and full of moisture.

  • Todd great article, just ordered my rigid foam and materials to frame the basement out. I live in Northwestern Indiana and will be finishing my basement as to your article. As an extra form of protection we used Epoxy on all the joints and used Zinsser waterproofing paint LX. We will be using 1 1/2" foam. I am unclear about a few things: How much adhesive should be used per 4x8 sheet of pink foam? Also for the pink foam which side goes towards the concrete?

    Lastly we have had a moisture problem on the Rim Joists where air seems to be getting trapped between the Batt Insulation and the Rim Joist creating dampness. Would this work well for the Rim Joist? We are looking for the best solution before we get to the drywall portion of the job. Happy New Year!

    • @ Alex - Thank for the compliment.

      The amount of adhesive really isn't all that important. We typically install a bead every 12" or so. Apply it to the foam, let it stand for 5 mins until it skims over then apply to the wall. Foam board works great on rim joists. Use 2" minimum and seal it in place with spray foam. Good luck.

  • Todd,

    I have glued 2" Foamular 250 to my concrete walls and taped the seams with Tyvek. I have built the 2x4 walls with 1/2" to 1" gap between the studs and foam. My plan is to use the encapsulate fiberglass insulation.(I prefer working with it). Is there a problem in using totally encapsulated fiberglass?

    Thanks,
    Nick

    • @ Nick - We've never used it so I can't give an opinion. I think it should work fine after what you've already done. Best of luck.

  • I have read all of your articles on foam board and vapor movement, but do not understand how the foam board approach solves the problem of trapped vapor. If the foam board is glued tightly to the wall (avoiding the air gap), the water vapor still needs to go somewhere. Why would it not just penetrate the foam board and cause the same problem as insulation? It seems to me that the foam board is as much of a vapor barrier as foil-backed insulation, which everyone agrees is a problem.

    Can you help clarify? (I have a below-grade basement (100-year-old house) that is freezing cold in the winter, so I am trying to insulate in some way. I also have some minor seepage that comes through the wall during heavy rains.)

    • @ Paul - Properly installed foam board insulation can create a very effective vapor barrier. Foam board also has the benefit of not promoting mold growth like fiberglass. There are two issues that you're trying to deal with. First of all the foundation walls are FULL of water and we want to keep that from getting to the framing and wallboard. Secondly we want to keep any moisture from the finished space from passing through the wall and hitting a cold surface where it could condense into liquid form and saturate the framing and wall finishes. Closed cell foam insulation products provide a great barrier to vapor movement. I hope this helps.

  • Todd,

    I have 40 year old pored concrete walls that have never had a water problem in turns of seepage, though have scaled off the original paint job considerably in some areas. Should they be repainted before gluing the foam board to them?
    Also, is a combination of foam board and batt insulation the way to go in insulating the areas above the sill plate? I can't tell you how many different opinions I've read on this.

    Thanks,
    Bob

    • @ Bob - In both situations it's all about a cost issue. Ideally we'd all insulate basements with spray foam if money were no issue. The idea of using both foam board and fiberglass is a more economical hybrid. Having said that I like to see a minimum of 2" of foam board on the rim joist, spray foamed in place....followed by additional fiberglass to supplement. Best of luck.

      • I have been searching endlessly and i believe @todd explained this finally for me. Here is what i am doing, I’m sorry if this scenario has been explained somewhere else.

        I have a 4 year old house (southern Ontario) it has a delta membrane on the outside foundation... builder has put up R12 fiberglass batts about 4-5 ft down on the concrete wall. I want to install durafoam EPS not XPS directly (PL Premium)against lower half of concrete wall. Tuck tape into existing upper half. Then put dricore down, add metal framing on top. I want to use XPS or EPS directly on the rim joists and seal around with canned spray foam then add roxul insulation behind everything. Then no more vapour barrier just drywall it up.

        I know this is not code, but can you foresee there being problems with this hybrid insulation method? thanks

Recent Posts

Framing Stick Nailer vs Coil Nailer

Which is Better a Stick Nailer or Coil Nailer? Framers have many choices in nailers…

12 months ago

How Many Roofing Nails Per Square of Shingles

Estimating How Many Nails for a New Roof When it comes to estimating materials for…

12 months ago

Composite / PVC Decking – Layout Tips & Advice

Composite / PVC Decking Layout Tips and Advice Composite and PVC decking have really changed…

1 year ago

Benefits of an ERV System (Energy Recovery Ventilator)

Benefits of ERV Systems (Energy Recovery Ventilator) If you're building a new home or doing…

2 years ago

Vermiculite Attic Insulation Abatement

Vermiculite Attic Insulation If your home was built before 1990 there is a chance it…

2 years ago

Nuisance Tripping of AFCI (Arc Fault) Circuit Breakers

Arc Fault (AFCI) Circuit Breakers Tripping Often An arc-fault circuit interrupter (AFCI) or arc-fault detection…

3 years ago